Construction
Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003
Conductor screen Semi-conductive thermosetting compound
Insulation Ethylene propylene rubber R-EP-90 to AS/NZS 3808
Insulation screen Semi-conductive thermosetting compound, tinned copper/polyamide braid to AS/NZS 1802:2003
Cradle separator Semi-conductive thermosetting compound comply to AS/NZS 1802:2003
Cable assembly Three screened power conductors and three EPR insulated (grey) and textile taped pilot conductors laid up with
right hand direction on cradle separator
Jacket Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant
Reinforcing braid Polyamide yarns
Jacket Thermosetting compound HD-90-CSP extra heavy duty oil resistant and flame retardant
Operating temp Minimum ambient temperature -25C Maximum conductor temperature + 90C
Cable tests AS/NZS 1802:2003
Marking Type of cable, size, manufacturer, year
Core ID Red, (grey), White, (grey), Blue, (grey)
Crush resistant central cradle construction
Flexible EPR insulation
Short circuit safety - screened conductors/semi-conductive cradle
Reinforced radial - strengthened heavy duty jacket
Oil resistant/flame retardant
Rated -25C to +90C
Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001
CERTIFICATE
PRODUCTION LINE AND TEST EQUIPMENT
PACKAGE